Search Results
Search this site
1045 results found with an empty search
- Specifications, LED Light Steady
be036520-aadb-47ef-a8a8-13536f954cdb GCL-113480.000X.S-LED Steady Light .pdf Download PDF • 667KB Download > > Specifications LED Light Steady
- Wiring, GCL GH.pdf
e538cbf0-ad0d-4405-aa6f-157ee2f41f14 GCL-GH_WiringDiagram .pdf Download PDF • 2.38MB Download > > Wiring GCL GH.pdf
- Drawing, GCL T SDMT DO.pdf
503b7329-3b2b-483f-90a5-b49676b25c58 Shop Drawings 112296_SDMT_TROLLEY_SX_DO .pdf Download PDF • 145KB Download > > Drawing GCL T SDMT DO.pdf
- Drawing, GCL GH RS DOL.pdf
27be3667-3ce4-42d3-811b-1b008900ad68 GCL GH RS DOL Drawing .pdf Download PDF • 83KB Download > > Drawing GCL GH RS DOL.pdf
- Instructions, Commercial Wi Fi Kit MD SD HD.pdf
3e951d24-ead6-4b25-80d5-dae52666e704 113459.02340-MED STD HVY .pdf Download PDF • 357KB Download > > Instructions Commercial Wi Fi Kit MD SD HD.pdf
- Specifications, GCL FDO.pdf
76c9a13d-49d1-4df1-b7da-7f099ad583cb GCL FDO Specifications .pdf Download PDF • 513KB Download > > Specifications GCL FDO.pdf
- Manual, GCL GT GH EXPF.pdf
dcc7ab05-ff18-4d47-8a06-b5c50eb447c1 GCL_GT_GH_Heavy Duty Operator Manual .pdf Download PDF • 9.75MB Download > > Manual GCL GT GH EXPF.pdf
- GCL Egress Operator | Genie Commercial Line Operator
GCL Egress OperatorSTANDURD-DUTY JACKSHAFTThe GCL-J Egress operator is designed for applications where access-controlled egress opening is required for emergency response ingress or exit. Advanced features and options provide considerable flexibility meeting job specific configuration needs. The GCL-J Egress operator works with emergency egress grilles having 30-cycle per hour or less duty requirement. Maximum door height: 24 feet. / Commercial Line Operators GCL-J EGRESS STANDURD-DUTY JACKSHAFT The GCL-J Egress operator is designed for applications where access-controlled egress opening is required for emergency response ingress or exit. Advanced features and options provide considerable flexibility meeting job specific configuration needs. The GCL-J Egress operator works with emergency egress grilles having 30-cycle per hour or less duty requirement. Maximum door height: 24 feet. Locate a Dealer Model #'s OPGSXJ1003RBEEG OPGSXJ5001RBEEG OPGSXJ1001RBEEG OPGSXJ1053RBEEG OPGSXJ5053RBEEG OPGSXJ5003RBEEG Advantages MultiVolt ® - Order phase specific operator for the job and have the ability to select the right voltage on the job site. Single Phase: 115/208/230 VAC Three Phase: 208/230/460 VAC Three Phase: 575 VAC available separately 16-character LCD display with intuitive setup menu. Provides current status and troubleshooting assistance. Internal receiver with the ability to individually add/delete up to 50 Intellicode ® transmitters directly from the LCD display, each with their own randomly assigned transmitter ID numbers. TensiBelt ® primary drive reduction eliminates need to adjust belt tension. EZ Limit ® provides for push to set limits that stay synchronized with door through long-term loss of power. Open/close/stop and setup keys included on control board. Modular design with optional boards for advance timer to close and auxiliary output functionality. Standard Features Limits are maintained after emergency egress grille operation. Upon restoration of power and/or rest of the egress activation device, the grille may be motor operated normally. Governor limits grille speed during egress operation. Release clutch disconnects operator drive train allowing grille travel to fully open position upon receipt of alarm signal, emergency egress push-button operation, or power loss. Continuous-duty AC motor with overload protection. Motor replaceable without changing limits. Thermally protected. EZ Limit ® electro-mechanical limits. Adjustable friction clutch. Pull cord release for emergency manual operation. Maximum run timer automatically adjusts to up and down run time. TensiBelt ® primary reduction. Chain and sprocket secondary reduction. Precision radial ball bearings in critical areas. 24 VDC disc brake with progressive braking. 2-year/20,000-cycle limited warranty. Delay on reverse. UL 325 Listed. 3-button control station. Programmable mid-stop. Product Information Shop Drawings Tech Support GCL-J Egress Operator Support Product Information: Product Brochure Operator Manual Product Specification Wiring Diagram -1PH Wiring Diagram - 3PH Door Chart EASY INSTALLATIONS, EFFICIENT OPERATIONS
- GCL-GT Explosion Proof | Genie Commercial Line Operator
GCL-GT Explosion ProofHEAVY-DUTY GEAR HEAD TROLLEY OPERATORThe GCL-GT explosion-proof operator is designed for standard-lift sectional doors that have up to 60 cycle/hour duty requirement. Maximum door height: 24 feet. / Commercial Line Operators GCL-GT Explosion Proof HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR The GCL-GT explosion-proof operator is designed for standard-lift sectional doors that have up to 60 cycle/hour duty requirement. Maximum door height: 24 feet. Locate a Dealer Model #'s OPGHXT5001BXP OPGHXT1003BXP Advantages Dynamic motor braking. Maximum run timer shuts down motor automatically when running time exceeds the time required to run between the limits plus five seconds. Heavy-duty worm gearbox for primary reduction. Delay on reverse. UL 325 momentary contact close compliant. 3-button control station. 2-year/20,000-cycle limited warranty. Drawbar disconnect for emergency manual release. Timed close enables door to automatically close after user-defined time delay between two seconds to four minutes. Standard Features FM APPROVED . The FM APPROVED mark, which is backed by scientific research and testing, indicates equipment specified for hazardous locations conforms to the highest standards. The explosion-proof motor is UL Listed and CSA Certified for hazardous location use in areas classified as Class I, Group D and Class II Group F & G. Hoist unit motors available in ½ horsepower single phase, 1 horsepower three phase and 3 horsepower three phase. Intrinsically safe design allows use of NEMA Type 1 control elements, such as push button stations, safety edges, and key switches. Limit overrun provides overrun adjustment from the down limit to fine tune the door seal to the floor. Cycle counter indicates the number of cycles logged for easy maintenance support. Voltage freedom - Order phase specific operator for the job and have the ability to select the right voltage on the job site. Single phase: 115/208/230 VAC or three phase: 208/230/460 VAC models available. Diagnostic LED visual indicators provide real-time status and trouble-shooting assistance. Open/close/stop and setup keys included on control board. Allows for monitored entrapment protection and momentary operation when used with select edge-sensing devices. Quiet trolley carriage with wear pads. Product Information Shop Drawings Tech Support GCL-GT Explosion Proof Operator Support Product Information: Product Brochure Operator Manual Product Specification Wiring Diagram EASY INSTALLATIONS, EFFICIENT OPERATIONS
- Specifications, 112809.0001.S
e4c1e43f-c659-42e6-9aec-c950bb885390 112809.0001.S Specification Sheet .pdf Download PDF • 220KB Download > > Specifications 112809.0001.S
- Drawing, GCL MZ RS DO.pdf
c6ca1c00-6a8e-45e5-99f0-68d2e9d7b501 GMZ-RS-DO .pdf Download PDF • 172KB Download > > Drawing GCL MZ RS DO.pdf
- GCL-MH | Genie Commercial Line Operator
GCL-MHMEDIUM-DUTY HOIST OPERATORThe new Z Series GCL-MH is designed for high or full-lift sectional and rolling doors that have a limited-duty cycle requirement. Advanced features and robust mechanical design combine to provide a medium-duty operator that is the new standard in the industry. / Commercial Line Operators GCL-MH MEDIUM-DUTY HOIST OPERATOR The new Z Series GCL-MH is designed for high or full-lift sectional and rolling doors that have a limited-duty cycle requirement. Advanced features and robust mechanical design combine to provide a medium-duty operator that is the new standard in the industry. Locate a Dealer Model #'s OPGMZH5011BL OPGMZH5011BR OPGMZHS5011BR OPGMZHS5011BL Advantages Rated for 15 cycles per hour operation, maximizing the performance of a medium-duty operator. Modular design with optional expansion boards for an advanced timer to close, and auxiliary output functionality. Included internal Intellicode® receiver learns up to 50 transmitters with randomly assigned identity numbers. Learn and delete individual transmitters directly from LCD display. Ball bearing motor with built-in thermal protection and ball bearings isolates motor for quiet operation, provides overload protection and extended motor life due to use of bearings over bushings. Open/close/stop and setup keys included on control board. Keeps all controls near the LCD display convenient for set up. Electric box isolation from the frame reduces vibration. Standard Features UL 325 2010 approved. EZ Limit® electro-mechanical limits. Max run timer automatically adjusts to up and down run time. TensiBelt® self-tensioning primary drive reduction. Delay on reverse. 16-character LCD display. 3-button control station. 2-year/20,000 cycle warranty. Programmable mid-stop. Right or left hand emergency hoist models available for manual operation. Built-in cycle count and trouble-shooting assistance via LCD display. Product Information Shop Drawings Tech Support GCL-MH Support Product Information: Product Brochure Operator Manual Product Specification Wiring Diagram Door Charts Warranty EASY INSTALLATIONS, EFFICIENT OPERATIONS
- GCL-J | Genie Commercial Line Operator
GCL-JSTANDARD-DUTY JACKSHAFT OPERATORThe GCL-J is designed for high or full-lift sectional and rolling doors that have a 30-cycle or fewer duty requirements. Advanced features and robust mechanical design combine to provide a standard-duty operator that sets a new standard for productivity. / Commercial Line Operators GCL-J STANDARD-DUTY JACKSHAFT OPERATOR The GCL-J is designed for high or full-lift sectional and rolling doors that have a 30-cycle or fewer duty requirements. Advanced features and robust mechanical design combine to provide a standard-duty operator that sets a new standard for productivity. Locate a Dealer Model #'s OPGSXJ1001B OPGSXJ1003B OPGSXJ1003BNV OPGSXJ1053B OPGSXJ5001 OPGSXJ5001B OPGSXJ5003 OPGSXJ5003B OPGSXJ5053 OPGSXJ5053B OPGSXJ7501B OPGSXJ7503B OPGSXJ7553B Advantages MultiVolt® - Order phase-specific operator for the job and have the ability to select the right voltage on the job site. Single Phase: 115/208/230V AC Three Phase: 208/230/460V AC 575V AC voltage models available separately Modular design with optional expansion boards for an advanced timer to close, and auxiliary output functionality. LCD display with intuitive setup menu. Provides real-time status and trouble-shooting assistance. Internal receiver with the ability to individually add/delete up to 50 Intellicode® transmitters directly from the LCD display. EZ Limit® provides for the push to set limits that remain synchronized with door through a long-term loss of power. TensiBelt® primary drive reduction eliminates the need to adjust belt tension. Open/close/stop and setup keys included on the control board. Keeps all controls near the LCD display convenient for set up. Standard Features UL 325 2010 approved. EZ Limit® electro-mechanical limits. MultiVolt® voltage simplification. Max run timer automatically adjusts to up and down run time. TensiBelt® primary reduction. Delay on reverse. 16-character LCD display. Advanced radio receiver displays and stores activation by transmitter ID number on the LCD screen. 3-button control station. 2-year/20,000 cycle warranty. Programmable mid-stop. Pull cord release for emergency manual operation. Product Information Shop Drawings Tech Support GCL-J Support Product Information: Product Brochure GCL-J Operator Manual NEMA4/4X Manual Product Specification Wiring Diagram Door Charts Warranty EASY INSTALLATIONS, EFFICIENT OPERATIONS
- GCL-Fire Door Operator | Genie Commercial Line Operator
GCL-Fire Door OperatorSTANDARD-DUTY HOIST OPERATORThe GCL Fire Door Operator is designed for rolling fire doors that have a 30-cycle/hour or fewer duty requirements. Advanced features and robust mechanical design combine to provide the next evolution in fire door operators. / Commercial Line Operators GCL-FDO STANDARD-DUTY HOIST OPERATOR The GCL Fire Door Operator is designed for rolling fire doors that have a 30-cycle/hour or fewer duty requirements. Advanced features and robust mechanical design combine to provide the next evolution in fire door operators. Locate a Dealer Model #'s OPGSXH5053FBR OPGSXH7501FBR OPGSXH7501FBL OPGSXH5003FBR OPGSXH5003FBL OPGSXH1053FBL OPGSXH1001FBL OPGSXH1001FBR OPGSXH1053FBR Advantages Floor level auto-reset. No manual intervention is required to reset fire door operator after a fire alarm or drop test. Upon reset of the fire alarm signal and test key switch, the fire door may be motor operated as normal. 24-hour battery backup provides extra protection in the event of a power loss. Governor controlled door descent. Configuration settings for automatic door opening after reset of the test key switch. User-configured time delay after an alarm or test signal before activation of door drop. Sash chain release ready for jurisdictions that require a fusible link. Intuitive configuration and trouble shooting of fire door and standard door functions through the built-in 16-character LCD display. Operator comes with a horn/strobe and test key switch, eliminating the need to purchase them separately. EZ Limit ® provides push-to-set limits that remain synchronized with door even during long term loss of power and activation of fire door drop. MultiVolt® - Order phase-specific operator for the job and have the ability to select the right voltage on the job site. Single Phase: 115/208/230V AC Three Phase: 208/230/460V AC 575V AC voltage models available separately 24 VDC disc brake with progressive braking standard. Cycle count available via LCD screen. TenisBelt® self-tensioning poly-V J belt primary reduction. Standard Features UL 325 Listed and FM Approved. LCD display with intuitive setup menu. Provides current status and trouble-shooting assistance. Internal receiver with the ability to individually add/delete up to 50 Intellicode ® transmitters directly from the LCD display Open/close/stop and setup keys included on control board. Keeps all controls used for setup conveniently near the LCD display. Modular design with optional boards for advance timer to close, edge sensing, or auxiliary output functionality. 3-button control station. 2-year/20,000 cycle limited warranty. Electrically interlocked emergency hoist for manual operation. Allows for momentary contact operation when using select Maximum run timer automatically adjusts to up and down run Delay on reverse. Product Information Shop Drawings Tech Support GCL-Fire Door Operator Support Product Information: Product Brochure Operator Manual Product Specification Wiring Diagram Door Charts Warranty EASY INSTALLATIONS, EFFICIENT OPERATIONS
- Drawing, GCL MZ SECT.pdf
f1fbffa4-8fb0-4502-8f11-7ee33391e3dd GMZ-SECT .pdf Download PDF • 95KB Download > > Drawing GCL MZ SECT.pdf
